 |
Transistorized Induction
Heating Power Supplies |
|
| |
| Features/Benefits: |
| |
 |
3, 10, 30 and 50 kHz with models available from 50 kW to 300 kW |
 |
Rated for continuous or intermittent duty |
 |
Variable ratio output isolation transformer for load impedance matching |
 |
Internal load matching capacitors for full power operation over a wide range of load conditions |
 |
Input power factor is 0.95 under all operating conditions |
 |
Output regulation accuracy is ±1% of rated power with ±10% line variance to ensure precise process control |
 |
Single control board. Field replaceable without adjustment for easy maintenance |
 |
Tempering mode for consistent very low power operation |
 |
Restart circuitry eliminates nuisance shutdowns caused by voltage transients, ground faults and shorted or arching loads |
|
|
|
|
 |
|
| |
 |
Power Supply For General Purpose Induction Heating |
|
| |
The UNIPOWER® UP16 is a self-contained, solid state transistorized power supply for hardening, tempering, bonding, coating, brazing and many other induction heating applications. A wide variety of single-turn and other low impedance heating coils can be properly matched with built-in load tuning capacitors and multi-tap output isolation transformer. |
| |
 |
Unitized Design For Stand-Alone Operation |
|
| |
| Simply connect three phase 415 V input power, cooling water and heating coil and you’re ready to begin heating. The cabinets are designed to accommodate a variety of fixtures, conveyors and part handling machines. Complete stand-alone control and monitoring include: Manual start/stop push buttons, heat level control with 10-turn lockable dial, four meters and annunciator lights to monitor all operating parameters. |
| |
 |
Remote or Computer Controlled Operation |
|
| |
| Remote control can be accomplished by connection to the user interface provided. Heat level can be controlled by a remote potentiometer or 0-10 V analog signal from a PLC. Options include a 4-20 mA process control signal or RS-232/485 interface for remote computer monitoring, data logging and control. |
| |
| SPECIFICATIONS: |
| ELECTRICAL OUTPUT |
UTILITY INPUT REQUIREMENTS |
CABINET DIMENSIONS Width x Depth x Height in. (mm) |
| kW Rating at Given Frequency |
kVA |
Cooling Water gpm (lpm) |
|
| 3kHz |
10 kHz |
30kHz |
50kHz |
| |
|
|
50 |
62 |
14 (53) |
36 x 30 x 76 (915 x 760 x 1930) |
| 75 |
75 |
75 |
|
94 |
14 (53) |
36 x 30 x 76 (915 x 760 x 1930) |
| |
|
|
100 |
125 |
14 (53) |
36 x 30 x 76 (915 x 760 x 1930) |
| 150 |
150 |
150 |
|
187 |
18 (68) |
36 x 30 x 76 (915 x 760 x 1930) |
| |
|
|
200 |
250 |
22 (84) |
52 x 40 x 76 (1320 x 1015 x 1930) |
| 300 |
300 |
300 |
|
375 |
26 (98) |
52 x 40 x 76 (1320 x 1015 x 1930) |
|
| |
| COMMON FEATURES: |
| Energy ConversionEfficiency |
85% minimum |
| Input Power Factor |
0.95 |
| Output Regulation |
Voltage, power or current |
| Regulation Accuracy |
±1% with ±10% line variance |
| Water Requirements |
95° F (max.) (35° C) |
| Power Requirements |
415 V, 3 phase, 50 Hz |
| Operator Controls |
Panel-mounted analog meters for voltage, frequency, current and output power. LED operation and diagnostic indicators. 10-turn potentiometer for control of output power, voltage or current. On/Off push buttons. |
| Safety Features |
Door interlocked disconnect switch and fast-acting semiconductor-type fuses. External, inlet and outlet cooling water pressure gauges. Water pressure differential switch and manual reset temperature switches on each water circuit. |
| * Specifications are subject to change without notice. |
|
| |
| |
|
|
 |
|
 |
| Induction heating & quenching |
|
Induction heating for brazing |
| |
|
|
 |
|
|
| Single shot induction hardening |
|
|
|