Self-Contained Induction Heating System |
|
| |
Features/Benefits: |
 |
3, 10 and 30 kHz with models available: 25 kW, 50 kW, 100 kW, 150kw, 200kw, 300kw. |
 |
Variable ratio output isolation transformer with optional external tap switch. |
 |
Internal load matching capacitors for full power operation over a wide range of load conditions. |
 |
Rectifier bridge and LC filter eliminate line noise interference. |
 |
Input power factor is 0.95 under all operating conditions. |
 |
Output regulation accuracy is ±2% with ±10% line variance to ensure precise process control. |
 |
Single control board. Field replaceable without adjustment for easy maintenance. |
 |
Digital heat timer 0-99.9 sec. |
 |
Remote control interface with 0-10 V or optional 4-20 mA remote analog input. |
 |
Optional UNICOOL closed loop water cooling and recirculating system. |
 |
Optional RS-232 interface for computer monitoring and control. |
 |
Built by the world's largest manufacturer of induction heating equipment. |
|
|
 |
|
| |
 |
Power Supply For General Purpose Induction Heating. |
|
| |
The UNIPOWER Tm UP1 2 is a self-contained system for hardening, tempering, bonding, coating, brazing and many other induction heating applications. A wide variety of single-turn and other low impedance heating coils can be properly matched with built-in load tuning capacitors and multi-tap output isolation transformer. An optional external tap switch allows the operator to safely and easily change the transformer ratio without tools. |
| |
 |
Unitized Design For Stand-Alone Operation. |
|
| |
Just connect three phase 415 v input power, cooling water and heating coil and you're ready to begin heating. The cabinets are designed to accommodate a variety of fixtures, conveyors and part handling machines. complete stand-alone control and monitoring include: Manual start/stop push buttons, heat level control with 10 turn lockable dial, four meters and annunciator lights to monitor all operating parameters. A digital timer is also included to precisely control the heating cycle. |
| |
 |
Remote Or Computer Controlled Operation. |
|
| |
Remote control from simple to complex can be accomplished by connection to the user interface provided. Heat time can be controlled from a simple foot switch, machine control relay or in a complex system by the process line PLC. Heat level can be controlled by a simple remote potentiometer, an optional 4-20 mA process control signal or with an analog 0-10 V signal from a PLC. An optional RS-232 interface is available for remote computer monitoring, data logging and control. |
| |
| SPECIFICATIONS: |
| Output Power at
10 and 30 kHz |
Input kVA (max.) |
Water Reqd. for 25 psi Pressure Drop |
Dimensions WxDxH in. (mm) |
Shipping Weight Pounds (kg) |
| 25 kW |
31 kVA |
7 gpm (26 Ipm) |
28x25x32 (711x635x812) |
380
(172) |
| 50 kW |
62 kVA |
7 gpm (26 Ipm) |
36x30x65 (914x762x1651) |
770 (350) |
| 1 00 kW |
124 kVA |
1 4 gpm (53 Ipm) |
36x30x65 (914x762x1651) |
850 (386) |
| 1 50 kW |
1 86 kVA |
1 8 gpm (68 Ipm) |
36x30x65 (914x762x1651) |
900 (409) |
| 200 kW |
240 kVA |
20 gpm (72 Ipm) |
36x30x65 (914x762x1651) |
900 (409) |
| 300 kW |
360 kVA |
24 gpm (88 Ipm) |
36x30x65 (914x762x1651) |
900 (409) |
|
| |
| COMMON FEATURES: |
| Energy Conversion
Efficiency |
85% minimum |
| Input Power Factor |
0.95 |
| Output Regulation |
voltage, power or current. |
| Regulation Accuracy |
± 2% with + 10% line variance |
| water Requirements |
95' F (max.) (35' c |
| Power Requirements |
415 V, 3 phase, 50 Hz |
| Operator Controls |
Panel-mounted analog meters for voltage, frequency, current and output power, led operation and diagnostic indicators. Built-in digital timer for heat cycle and automatic shutoff. Manual/timed selector switch. External six-position transformer tap switch for impedance matching. Ten turn output control potentiometer. On/Off for push buttons. The bench-top 25 kw model has only one panel-mounted meter with a four position selector switch. |
| Safety Features |
Door interlock, circuit breaker and fast-acting semiconductor-type fuses. Lockout to prevent transformer tap switching under load. External, inlet and outlet cooling water pressure gauges. Water pressure differential switch and manually reset temperature switches on each water circuit. |
| Specifications subject to change without notice. |
|
| |
|